Auto bed-leveling.

  • Testprint

    Printed in 3mm PLA. 0.1mm @ 100mm/s 215 C.

Make: 2015 3D Printer Shoot Out Test

Printmaster3D Portable. Foldable 3d printer.

Dimensional Accuracy .Score 5

Overhang test . Score 5

Bridging Performance. Score 4

Negative Space Tolerances . Score 4

 Fine Positive Space Features Performance . Score 4

Mechanical Resonance in XY . Score 2

Mechanical Resonance in Z . Score 2

Total score .26

3mm PLA . Simplify3D, 0.1mm, 220C , 100mm/s

 

 

  • Dimensional Accuracy

    •Assign the print a “1” if average deviations in X or Y are greater than 0.4mm.
    •Assign the print a “2” if average deviations in X or Y are between 0.4 and 0.3mm.
    •Assign the print a “3” if average deviations in X or Y are between 0.2 and 0.3mm.
    •Assign the print a “4” if average deviations in X or Y are between 0.1 and 0.2mm.
    •Assign the print a “5” if average deviations in X or Y are between 0 and 0.1mm.

  • X = 19.97mm
    Score :5

  • Y=20.02mm
    Score:5

  • Bridging Performance

    Assign a “1” if any bridge has dropped infill.
    Assign a “2”if only the longest two bridges have dropped infill.
    Assign a “3” if none of the bridges have dropped infill, but all have dropped perimeters.
    Assign a “4” if the shortest two bridges compiled without any dropped perimeters.
    Assign a “5” if all bridges compiled without any dropped perimeters (drooping of less that 2mm is acceptable).
    Score: 4

  • Bridging Performance

  • Negative Space Tolerances

    Assign the print a “0” if no pins can be removed.
    Assign the print a “1” if the 0.6mm radial tolerance pin can be removed.
    Assign the print a “2” if the 0.6mm and 0.5mm radial tolerance pins can be removed.
    Assign the print a “3” if the 0.6, 0.5, and 0.4mm radial tolerance pins can be removed.
    Assign the print a “4” if the 0.6, 0.5, 0.4 and 0.3mm pins can be removed.
    Assign the print a “5” if all pins can be removed.
    Score:4.

  • Fine Positive Space Features Performance

    Assign the print a “1” if the spires did not compile due to extruder jam/lack of material flow.
    Assign the print a “2” if the spires compiled but are densely connected by strands of material.
    Assign the print a “3” if the spires compiled and there are some connecting strands but the main deviation from target geometry is due to volume flow issues (under- or over-extrusion).
    Assign the print a “4” if the spires compiled, there are no connecting strands, but there are volume flow issues.
    Assign the print a “5” if the spires compiled and there are no connecting strands and no stepping or ridging due to volume flow issues.
    Score:4.

  • Fine Positive Space Features Performance

  • 0.5 scale Marvin 40 micron 0.04mm

  • 0.4 scale Marvin 3o micron 0.03mm .